The Furman CN-1800S SmartSequencing Power Conditioner combines professional 15-amp AC power distribution, intelligent power sequencing, surge protection, and noise filtration in a compact 1RU rackmount design. Built for commercial audio/video installations, the CN-1800S allows equipment to be powered on and off in a controlled sequence, helping prevent the unwanted speaker pops, amplifier stress, and excessive simultaneous inrush current associated with powering an entire system at once.
Featuring Furman's SmartSequencing technology, Series Multi-Stage Protection (SMP), Linear Filtering Technology (LiFT), and Extreme Voltage Shutdown (EVS), the CN-1800S provides comprehensive power management for sensitive AV equipment. Nine protected outlets, RS-232 control, configurable sequencing delays, and optional BlueBOLT network integration make it an effective solution for houses of worship, auditoriums, conference facilities, commercial sound systems, and centralized equipment racks.
Features & Benefits
SmartSequencing Power Management
Furman's SmartSequencing technology allows connected equipment to power on and off in a controlled sequence using the front-panel key switch, pushbutton, or compatible remote control system.
This is particularly important in professional sound systems, where signal-processing equipment should generally power on before amplifiers and amplifiers should power off first.
By staggering startup and shutdown, the CN-1800S helps reduce unwanted audio transients and simultaneous power demands.
Three Independently Sequenced Outlet Banks
The CN-1800S provides six rear-panel sequenced outlets organized into three independently controlled duplex outlet banks.
Each bank is controlled by its own relay, allowing equipment to receive power in a predetermined order.
The unit also includes two unswitched rear outlets and one unswitched front convenience outlet for equipment that requires continuous power.
All nine outlets share the unit's maximum 15-amp capacity.
SMP Series Multi-Stage Surge Protection
Furman's Series Multi-Stage Protection (SMP) technology helps protect connected equipment against damaging AC spikes and transient surges.
Its non-sacrificial protection design provides a published 188V peak clamping level when tested with a 6000V/3000A surge input.
The protection system operates line-to-neutral with zero ground leakage, helping avoid contamination of the equipment ground.
LiFT Linear Filtering Technology
Linear Filtering Technology (LiFT) reduces unwanted electrical noise on incoming AC power.
The CN-1800S provides published noise attenuation of 10 dB at 10 kHz, 40 dB at 100 kHz, and 50 dB at 500 kHz.
This helps minimize AC line interference affecting sensitive audio, video, and digital equipment.
Extreme Voltage Shutdown Protection
The CN-1800S includes Extreme Voltage Shutdown (EVS) circuitry to disconnect connected equipment when incoming voltage reaches unsafe levels.
Published protection thresholds include approximately 77 VAC for undervoltage and 145 VAC for overvoltage conditions, with specified tolerances.
The unit supports configurable manual or automatic reset following an overvoltage event.
Primary and Secondary SmartSequencing
The CN-1800S supports communication between compatible Furman SmartSequencing devices.
A primary sequencer can coordinate the power-up and power-down operations of multiple secondary units, allowing larger installations to manage equipment across different racks or areas.
SmartSequencing connections use dedicated Phoenix-style terminal connectors and support nominal communication distances of approximately 1,000 feet.
RS-232 and Optional BlueBOLT Integration
An integrated RS-232 interface allows the CN-1800S to communicate with compatible third-party AV control systems.
Optional network connectivity is available through the separately sold Furman BB-RS232 Ethernet adapter.
When equipped with compatible network hardware and supported services, the unit can provide IP-based control and monitoring through BlueBOLT.
Ethernet and BlueBOLT connectivity are not built into the standard CN-1800S.
Configurable Sequencing Delays
Front-panel DIP switches and a fine-adjustment potentiometer allow installers to customize sequencing behavior.
Available settings include delay configuration, primary/secondary operation, momentary or maintained control, and EVS reset behavior.
A security cover helps prevent unauthorized changes to these settings.
Front-Panel Key Switch and Diagnostics
The CN-1800S features a three-position key switch with ON, OFF, and REMOTE positions.
A protected pushbutton provides another method of initiating sequencing operations.
Front-panel diagnostic indicators display operating information such as sequencing status, primary and secondary communication, protection status, and extreme-voltage conditions.
Key Features
-
15-amp SmartSequencing power conditioner
-
Standard 1RU rackmount design
-
Nine NEMA 5-15R outlets
-
Six sequenced rear outlets in three relay-controlled banks
-
Two unswitched rear outlets
-
One unswitched front convenience outlet
-
Furman SmartSequencing technology
-
Primary/secondary sequencing for compatible systems
-
Series Multi-Stage Protection (SMP)
-
Linear Filtering Technology (LiFT)
-
Extreme Voltage Shutdown (EVS)
-
Configurable manual or automatic overvoltage reset
-
Integrated RS-232 control interface
-
Optional BlueBOLT network management with compatible adapter
-
Configurable sequencing delays
-
Front-panel three-position key switch
-
Protected sequencing pushbutton
-
Front-panel diagnostic LED indicators
-
15A thermal circuit breaker
-
Fixed 10-foot power cord with NEMA 5-15P plug
-
Designed for commercial and professional AV installations
Ideal Applications
-
Houses of worship
-
Commercial sound systems
-
Auditoriums and theaters
-
Corporate conference facilities
-
School and university AV systems
-
Broadcast and recording facilities
-
Professional equipment racks
-
Multi-zone distributed audio systems
-
Live performance venues
-
Commercial AV control installations
Furman CN-1800S Technical Specifications
|
Specification
|
Details
|
|
Manufacturer
|
Furman
|
|
Model
|
CN-1800S
|
|
Product Family
|
Contractor Series
|
|
Product Type
|
SmartSequencing Power Conditioner
|
|
Mounting
|
19-Inch Rackmount
|
|
Rack Height
|
1RU
|
|
Nominal Line Voltage
|
120 VAC
|
|
Published AC Input Range
|
90–139 VAC, 50/60 Hz
|
|
Maximum Current Rating
|
15 Amps, Combined
|
|
Circuit Breaker
|
15A Thermal, Front-Panel Reset
|
|
Total Outlets
|
9 × NEMA 5-15R
|
|
Rear Sequenced Outlets
|
6, Across 3 Relay-Controlled Banks
|
|
Rear Unswitched Outlets
|
2
|
|
Front Unswitched Outlets
|
1
|
|
AC Power Cord
|
Fixed, 10 ft, 3/14 AWG
|
|
Power Plug
|
NEMA 5-15P
|
|
Surge Protection
|
Series Multi-Stage Protection (SMP)
|
|
Spike Protection Mode
|
Line-to-Neutral, Zero Ground Leakage
|
|
Spike Clamping Level
|
188V Peak at 6000V/3000A Input
|
|
Published Response Time
|
1 Nanosecond
|
|
Maximum Surge Current
|
6,500 Amps
|
|
Undervoltage Protection
|
EVS, 77 VAC ±3 VAC
|
|
Overvoltage Protection
|
EVS, 145 VAC ±5 VAC
|
|
Overvoltage Reset
|
Configurable Manual or Automatic
|
|
AC Filtering
|
Linear Filtering Technology (LiFT)
|
|
Noise Attenuation
|
10 dB at 10 kHz
|
|
Noise Attenuation
|
40 dB at 100 kHz
|
|
Noise Attenuation
|
50 dB at 500 kHz
|
|
Front Key Switch
|
3 Positions: ON, OFF, REMOTE
|
|
Front Pushbutton
|
Protected by Security Cover
|
|
Delay Configuration
|
DIP Switches and Fine-Adjustment Potentiometer
|
|
SmartSequencing Connection
|
Phoenix-Style 4-Pin Screw Terminals
|
|
Sequencer Link Distance
|
Approximately 1,000 ft Nominal
|
|
RS-232
|
Yes, DE-9 Connector
|
|
IP Control
|
Optional BB-RS232 Adapter Required
|
|
BlueBOLT Compatibility
|
Optional, With Compatible Adapter and Service
|
|
Remote Control Connections
|
Phoenix-Style Screw Terminals
|
|
No-Load Power Consumption
|
10 Watts
|
|
Operating Temperature
|
5°C to 40°C
|
|
Operating Humidity
|
Below 90% Relative Humidity
|
|
Chassis Width
|
17 Inches
|
|
Rack Faceplate Width
|
19 Inches
|
|
Height
|
1.75 Inches
|
|
Depth
|
10.5 Inches
|
|
Weight
|
Approximately 12 lbs
|
|
Safety
|
NRTL-C
|
|
Environmental Compliance
|
RoHS
|
Installation and Compatibility
The Furman CN-1800S is designed for installation in standard 19-inch equipment racks and operates from a properly grounded 120V AC power source.
Its six sequenced rear outlets can be assigned to equipment requiring staged startup and shutdown. The three unswitched outlets are intended for equipment that must remain powered independently of the sequencing process.
For larger installations, compatible Furman SmartSequencing units can be interconnected using the dedicated primary and secondary control terminals.
The RS-232 interface supports integration with compatible AV control systems. Optional Ethernet and BlueBOLT capabilities require additional compatible hardware and configuration.
Important Installation Notes:
-
The maximum combined load across all nine outlets is 15 amps.
-
The CN-1800S is a power conditioner and sequencer, not a voltage regulator or UPS.
-
The front and rear unswitched outlets do not follow the three-bank sequencing operation.
-
Network control requires an optional compatible adapter.
-
Sequencing delays and protection settings should be configured for the connected equipment.
Why Buy the Furman CN-1800S from Audio Supply?