The Shure SM86 is a Cardioid Condenser Vocal Mic. This mic gives you all the advantages of Shure's SM line with condenser mic clarity. It's ruggedly built to handle touring, with a frequency response tailored for clear reproduction of vocals. The cardioid polar pattern minimizes background noise and feedback. The SM86 has a built-in 3-point shock mount for minimizing handling noise and a 2-stage filter for reducing breath noises and pops. It requires phantom power. The SM86 requires phantom power. This may be supplied to the microphone from an external power supply (such as the Shure model PS1A) or directly from preamplifiers, mixers, or consoles with built-in phantom power. Suitable sources should provide 11 to 52 Vdc phantom voltage.
General Rules for Use
- Do not cover any part of the microphone grille with your hand, as this will adversely affect microphone performance.
- Aim the microphone toward the desired sound source (such as the talker, singer, or instrument) and away from unwanted sources.
- Place the microphone as close as practical to the desired sound source.
- Work close to the microphone for extra bass response.
- Use only one microphone to pick up a single sound source.
- For better gain before feedback, use fewer microphones.
- Keep the distance between microphones at least three times the distance from each microphone to its source (“three to one rule”).
- Place microphones as far as possible from reflective surfaces.
- Add a windscreen when using the microphone outdoors.
- Avoid excessive handling to minimize pickup of mechanical noise and vibration
SM86 Features
- Condenser capsule provides studio-quality sound
- Rugged design handles the abuses of touring
- Tailored frequency response for clear reproduction of vocals
- Cardioid polar pattern minimizes unwanted background noise
- Works excellently with both stage monitors and in-ear personal monitors
- Built-in 3-point shockmount minimizes handling noise
Sm86 Specifications
- Transducer type: Condenser (electret bias)
- Frequency response: 50 to 18,000Hz
- Polar Pattern: Cardioid
- Output Impedance: 150? at 1kHz (Recommended minimum load impedance: 600?)
- Sensitivity (at 1,000Hz): Open Circuit Voltage: -50dBV/Pa (3.15 mV) (1 Pa = 94dB SPL)
- Output Clipping Level: 1000? Load at 1,000Hz: 3dBV (1.41 V)
- Maximum SPL (at 1,000Hz): 1000? load (1% THD): 147dB
- Self-Noise: 23dB typical, A-weighted
- Dynamic Range (1000?): 124dB (maximum SPL to A-weighted noise level
- Signal-to-Noise Ratio: 71dB at 94dB SPL (IEC 651)*
- *S/N ratio is difference between 94dB SPL and equivalent SPL of self-noise A-weighted
- Polarity: Positive pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of the output connector.
- Power (Phantom Supply Requirement): 11 to 52 VDC, positive at both pins 2 and 3
- Current Drain: 5.2 mA
- Connector: Three-pin (XLR) professional audio
- Dimensions (H x W): 183mm x 49mm, 7.2" x 1.92"
- Net Weight: 278g (9.8oz.)
- Environmental Conditions;Operating: -18° to 60° C (0° to 135° F) (relative humidity >90%), Storage: -29° to 74° C (-20° to 165° F) (relative humidity >80%)